4 weeks ago I broke the bottom drawer as it was caked in built-up ice. Meant to be a frost-free freezer but whatever.

Yesterday night I couldn't get the bottom drawer free again so something is wrong.

The freezer manual says that taking the panel off to expose the pipes/fan on the inside of the freezer requires an engineer visit. Screw that.

3 screws and the panel came off, the fan is attached to the panel so I unclipped the electric connection.

Immediately saw the problem. From the bottom of the panel to about 4 inches up, it was caked in ice in the shape of the inside of the panel.

Hot water spray and a fan, with a bit of poking with the handle of a spoon got all the ice off. Used the spoon to straighten all the fins.

Poured some hot water down the drain hole that was previously clogged with ice. Cleaned it a little with a straw cleaner. Poured a little more water down and it drained away quickly. Hopefully fixed now.

Gave it a thorough clean. Misses commented on how clean it looked. Chuffed.

all 15 comments

sorted by: hot top controversial new old
[–] 16 points 1 month ago (1 child)

I like your user name, but you are neither lazy nor a nooblet. Well fixed, my good sir

  • source
  • hideshow 1 child comment
  • [–] 12 points 1 month ago (1 child)

    Does this fridge have a heating element to defrost the evaporator? It kind of sounds like maybe the failure of the heating element is the root cause of the ice build up.

  • source
  • hideshow 1 child comment
  • [–] 10 points 1 month ago

    Screw that.

    No, clearly you said 'unscrew" that.

  • source
  • [–] 6 points 1 month ago (3 children)

    I would start planning to replace that fridge. My experience is when this kind of stuff starts to happen, that fridge is starting to die.

    I hope it lasts you another year, but it's always best to be prepared.

  • source
  • hideshow 3 child comments
  • [–] [S] 2 points 1 month ago (2 children)

    I have a little over 12 months left on the warranty.

    Interestingly the freezer is now at -30C but is only set to -18C which is a bit odd

  • source
  • parent
  • hideshow 2 child comments
  • [–] 1 point 1 month ago

    You should call to have a technician out under the warranty ASAP. A frost-free freezer should not have that level of ice build up, and it definitely shouldn't be out running the set temperature by that much.

    FYI - some warranties have a clause that problems must be reported "in a timely manner" (usually 30 days) or they won't be covered because ignoring a problem can make bigger (more expensive to fix) problems. It's difficult to enforce outside of a person saying "well it's been doing this for weeks!" thinking that will get sympathy and a faster repair - spoiler alert it won't.

  • source
  • parent
  • [–] 5 points 1 month ago (1 child)

    I don’t think I’ve ever had a frost-free freezer be completely frost-free, even when we’re carefull not keeping it open for to long.
    These days we de-ice it every winter where the food can be outside.

    Good job fixing it!

  • source
  • hideshow 1 child comment
  • [–] 1 point 1 month ago

    Nice alliteration

  • source
  • [–] 1 point 1 month ago (2 children)

    When mine did that i found out the tail of the drain in the pan was a thin rubber tube with a tendency to collapse in on itself. Wedged a bolt to keep it open and never had a problem since

  • source
  • hideshow 2 child comments