I have two fridge/freezers and a chest freezer. None of them are "smart" and all use mechanical controls. A few months ago I put all three on zigbee plugs, and created an automation to monitor and notify via ntfy if it detects any problems:

  • Notify if compressor doesn't switch between on/off state for two hours (Based on power usage, detects stuck thermostat, door left open, defrost cycle issue, failed compressor, plug fallen out the socket or anything else which causes the fridge to not run normally). This uses a helper binary sensor which shows "on" if power usage > 40W and fires the notification if the state of the binary sensor doesn't change for more than 2h.

  • Notify if any of the plugs are turned off or go offline for more than 15 minutes. (This is what fired overnight)


Just after midnight, I was woken by a notification saying two of them had gone offline at the same time. Got out of bed to check and found the RCD breaker feeding two of them had tripped. Isolated the fault to the kitchen fridge, it trips the breaker the moment it is turned on. Left the kitchen fridge unplugged and transferred the contents to the other two plus a spare in the garage. Without this automation it's likely I wouldn't have found this problem until the following evening after work when it would have been too late.

Interested to hear if anyone else does similar monitoring using their HA?

you are viewing a single comment's thread
view the rest of the comments

What I wound up doing for my pond/fish tanks/basement is using an esp8266 with these: https://www.espboards.dev/sensors/ds18b20/. That reports into Home Assistant. It was really easy to program! That allows me to get the water temp and air temp for fish oriented things.

  • source