Added a PEI plate for my Artillery Genius using bull clips, and after leveling the leveling/adhesion test print comes out like this. Is this just me leveling the bed too close to the nozzle, or is it the pei plate not heating up as much as the original glass bed? It's at 60c btw

you are viewing a single comment's thread
view the rest of the comments
[–] 6 points 10 months ago (8 children)

Looks to me that you could try raising the nozzle a fraction. Your extrusion looks flakey though, so it could be the nozzle as well. But on the other hand, if your nozzle is too close to the bed, that will inhibit extrusion as well.

  • source
  • hideshow 8 child comments
  • [–] [S] 5 points 10 months ago (7 children)

    Yeah turns out the plate got bowed during shipping and was not exactly flat. After making it flatter and some cleaning, it's looking a lot better.

  • source
  • parent
  • hideshow 7 child comments
  • [–] 2 points 10 months ago (2 children)

    Looks like you're still way too close to the bed, I'd (numerically) increase Z-offset so you have more distance between the nozzle and the bed

  • source
  • parent
  • hideshow 2 child comments
  • [–] [S] 1 point 10 months ago (1 child)

    Thanks for the feedback. I'm doing it by the paper method, so I might be guessing the right amount of friction wrong. Is there a trick to figuring out the right amount of friction using the paper?

  • source
  • parent
  • hideshow 1 child comment
  • [–] 2 points 10 months ago (2 children)

    Looks better, but IMO it looks like it's still calibrated too close to the bed. In some places it looks like the material has been smushed into the surface, and in others it looks like ridges have formed between the lines where the nozzle has pushed excess material around. https://cdn.help.prusa3d.com/wp-content/uploads/First-Layer-Calibration-04.jpg

  • source
  • parent
  • hideshow 2 child comments
  • [–] [S] 1 point 10 months ago (1 child)

    Makes sense, thanks for the picture. Is there a trick to the right friction when using the paper method?

  • source
  • parent
  • hideshow 1 child comment
  • [–] 2 points 10 months ago

    I think it's more of an art form than an exact science to get perfect calibration using the paper method. It gives a decent starting point for further manual adjustment though. Personally I prefer to put a lamp behind the printer, and then babystep the nozzle down until I can no longer see any gap between it and the bed, but that also usually requires a few minor adjustments afterwards.

  • source
  • parent