Velcro costs so much more than zip ties.
comments
We learned how to braid rope in scouts.
It's awful considering braided cable sleeve is orders of magnitude cheaper than IT labor.
The IEEE specs up to 2.5GBaseT do not specify any shielding for cabling.
It still happens, the modern standards just handle these impairments better with line coding, active equalization, and more sensitive modem electronics. And obviously now we have shielding requirements in the PHY for 2.5G and above. But basically as DSP got cheaper and more compact, they were able to throw more compute at the problem which made a huge difference.
Velcro is almost always the way to go with cable management. Zip ties can easily damage the wire and encourage messy wiring since you have to cut and replace every one to change a single wire.
Wire lacing is OK for permanent installations, but good luck changing anything.
When you have automated most of your job, but you still take Adderall every day.
*sextuple
Yes, in theory. But in practice it depends on the frequencies.
Even if interference is insignificant, looping the wires around a metal core (which braiding does) creates a different impedance and can degrade the signal.
Would the twisted pairs prevent cross talk between two separate cables like it does individual wires?
Ah yes, a twisted pair.
Granted I'm no network engineer. But I have made many of my own cat5's through the years and I have not seen one since I was unable to legally drive.
They only teach girls how to braid in pre school then ostracise them out of becoming power techs.
Most ethernet cable is UTP, literally "unshielded twisted pair." Shielded cable is much more expensive and less physically flexible due to the metal jackets, so people dont tend to buy it by default.
You can argue the jacket is shielding, but mostly ethernet cable is not shielded. The braiding will cause problems, but likely very minor ones based on the length of the the run that CRC will compensate for.
You could also use tape tags on the ends, either color or number codes. Just mark both ends of each cable.
You still have trace each cable between the patch panel and the switch or thing could end up on the wrong subnet.
I hear you, but how often have you had to swap out a cable compared to how often have you had to deal with a rats nest? This isn't a whole lot different than zip tying groups of cables together.
IMHO this would be even better with 6 different colors per braid. Then you could trace a cable in a few seconds while also not having a rats nest.
Edit: oops, this was supposed to be a reply to another comment.
Or you could mark the bad one, replace the whole set, then unbraid and toss the marked one later in a dumb meeting you have better things to do than attend or something :p
I don't think I've seen a single data cable that didn't have some kinda shielding since the early nineties.
I actually had to teach someone in my uni course how to braid power cables for a induction motor. Do they not teach basic skills in preschool anymore?
God forbid you have to swap out a cable or a port does on the switch. You will spend 20 min trying to figure out what cable goes where
IT with an E
Exactly the first thought I had, fellow old-timer.
Sure, a long as those cables are shielded. Crosstalk was a real thing "back in my day".
That's actually not that awful. Time consuming and you better not need to change the loom after it's done, but that doesn't become spaghetti that easily. At least not until someone adds few individual (and way too long) cables tangled to those.