By nancou_(nankou),sauce

Here is a capacitor (with lemon tea)

It is broken so I am gonna replace it

But there is a problem. The new I brought does not have short terminal as shown below.

The new capacitor (reference image)

As some cables use "short" terminal, maybe I should grind the terminal with sandpaper to fit the cables?

you are viewing a single comment's thread
view the rest of the comments
[–] 3 points 1 year ago

It's a motor run capacitor, says it's usually for an AC unit

https://datasheet4u.com/pdf-down/B/3/2/B32335_EPCOS.pdf

Can't find anyone who stocks it or the more recent part numbers, even if they say they are still in production.

C is your common, H is the compressor, F is the fan

Do you now which wire went where when you disconnected it?

The new cap appears to say Fan on one side, use the lead that went to F on the old one. The lead from H should go to Herm, and C should go on the remaining cluster.

Not sure what you mean by short, but if can make them fit snuggly it should work.

  • source