Replaced the capacitor and all has been running cool again for about a week. Replaced my neighbor's too. Theirs stopped working again after 48 hrs. One more replacement on theirs and we're at 72 hrs of runtime since replacement.

you are viewing a single comment's thread
view the rest of the comments
[–] 3 points 2 months ago (4 children)

What is the symptom that says it's the capacitor? I'm guessing it starts the compressor, so the fan runs but no cold?

  • source
  • hideshow 4 child comments
  • [–] 5 points 2 months ago* (1 child)

    Usually they bulge and if you know what it's supposed to look like, it's quite apparent that it's dead.

    The cap is what's used to provide the power necessary for the initial start, so, it that doesn't happen, it's the quick and easy thing to check (I keep a set of the ones mine takes on a shelf ... 30 for a set of 2 and 10 minutes of time to replace or a small fortune for an HVAC guy to replace)

    Your inside furnace fan might still run, but, on mine at least, the outside unit fan doesn't run if the cap is dead

  • source
  • parent
  • hideshow 1 child comment
  • [–] [S] 1 point 2 months ago

    Pretty much anything - outside fan isn't running? Outside fan is running but air not cool? Obv it can be more, but it's a very cheap first attempt. And cheap enough to keep on hand like you do

  • source
  • parent
  • [–] 1 point 2 months ago

    the symptom is either the fan won't run, or the compressor won't run.

    these are typically dual eated capacitors. eg 25/5. the 25 powers the compressor, and the 5 would power the fan. both, or one of those can fail resulting in nothing running, or the system straining to turn over

  • source
  • parent
  • [–] 1 point 2 months ago

    If you have multimeter, even a cheap one will do, you can test them. there are you tube videos that can show you how to test them even with a cheap meter that doesn't have a capacitance test setting, just ohms.

  • source