[–] 33 points 1 year ago (3 children)

TÜV sagt nein.

DIN 18040

Ramps, external ramp, internal ramp, handrail

Access areas at entrances with a gradient of 3% or more must be designed as ramps. With a length of up to 10 m, a longitudinal gradient of up to 4% is permitted. Ramps must be safe to walk and drive on. Drainage must be ensured in the outdoor area.

Ramps in public areas must always be designed in accordance with DIN 18040-1 with a maximum gradient of 6% and without a transverse gradient!

  • Longitudinal gradient: max.6%
  • Transverse gradient: 0
  • Clear width: min.1.20m
  • Length of ramp run: max.6.00m
  • Length of intermediate landing: min.1.50m
  • Height of wheel deflector: min.0.10m
  • Height of handrail on both sides: 0.85 to 0.95m with flush finish
  • Handrail diameter: 0.035 to 0.04m
  • source
  • hideshow 3 child comments