[–] [S] 19 points 10 months ago

Yeah there was, they have burn over protection in case they get overrun by fire, this one from South Australia for example has a few features:

Key features standard across all response vehicles:

  • Cabin deluge systems for cabin glass protection.
  • In-cabin breathing systems for crew oxygen supply for burn over events.
  • Cabin crew protection (window curtains, where required) as radiant heat shields.
  • In-cabin pump control to enable operation of Cabin Deluge from the cab.
  • Under-cabin heat shields to reduce radiant heat penetration of cabin structures.
  • Tyre spray systems to reduce radiant heat.
  • Updated visibility markers to new safety standards to improve fleet visibility on fire grounds and when responding.

https://www.cfs.sa.gov.au/home/criimson/cfs-completes-most-significant-safety-upgrade-to-its-fleet-since-ash-wednesday-fires-issued-23-mar-10300006849/

  • source
  • parent