[–] 10 points 1 year ago (1 child)

In the early 70s the city I used to live in replaced all their old wooden water lines with concrete/asbestos pipes. They are now digging up the asbestos lines and replacing them with plastic. I do not know what the eventual plumbing will look like once they find out how the plastic is killing them.

  • source
  • [–] 2 points 1 year ago

    It really doesn't have anything to do with 220v vs 120v systems. You can easily boil water with 15 amps at 120 volts. We used to have dishwashers with strong enough heating elements in the US to do this from cold running on 120v. It is a lot more to do with the efficiency standards set by Department of Energy, starting in 1994 and then further restricted in 2013 to maximum 307 KWh/year and 5 gallons of water per cycle. Prior to this, dishwashers in the US worked very differently than they do today. This is also why dishwashers in the US do a terrible job of drying dishes now - not enough energy to power a bigger heating element like they used to have.

    On top of that, many current built and sold machines (at least in the US) are in fact more complicated than let on above, even the cheaper units, just not how you'd think. In order to try to squeeze as much performance out of those efficiency standards above, many have a turbidity sensor in the water flow path that checks how "dirty" the water is. If it doesn't detect much, they will stop the cycle early, which means they "use less energy per year on average" (for the above legislation) and then can use more energy in a cycle "that needs it". This often has a downside of people that significantly pre-rinse their dishes get really bad results from a dishwasher because the cycles will end so early the detergent hasn't even fully dissolved yet and will be scattered and stuck to the dishes.

    They are correct though that most don't have temperature sensors in them, because frankly it doesn't matter - they are either able to get to the needed temperature with the energy they are allowed or they aren't. The only benefit of letting the machine know would be so it can display an error code to alert the user there is a water temperature problem (but most mfrs don't want to do that because the average user won't even bother looking up the error code and will just try to return the product or get a warranty service call, both of which cost the mfr money).

  • source
  • parent
  • context
  • [–] [S] 5 points 1 year ago

    It's fr and not a joke. If you grow up here, you're usually told. Some aren't aware of it though. We keep giant hot water tanks ready to go.

    This is the typical think most people have for old construction. Not sure about new construction. It's usually stuck in a closet or the basement:

    https://www.homedepot.com/b/Plumbing-Water-Heaters-Tank-Water-Heaters-Electric-Tank-Water-Heaters/30-gal/N-5yc1vZ2fkoqeqZ1z1t3nf

  • source
  • parent
  • context
  • [–] 9 points 1 year ago

    For countries without lead issues, it is still a bad idea as hot water tanks can be hosts to a bunch of shit you definitely don't want to ingest.

  • source
  • [–] 10 points 1 year ago* (1 child)

    Yeah that's not been true for about 50 years.

    We replaced all our lead, and it's a legal requirement to if you find a lead pipe in a system, replace it no matter what (even in listed buildings) or disable the outputs entirely (the latter is more common in VERY OLD buildings, with people then adding a new system somewhere else, sometimes with exposed pipework rather than having to potentially damage walls.)

    We also just don't do hot water tanks any more usually, instead doing on-demand boilers.

    Does mean that the hot runs cold for about a minute, but it balances out

  • source
  • parent
  • context
  • [–] 1 point 1 year ago (2 children)

    We have a small one and you can get loads of hot water out of it non stop. I get your idea but I don't think it works for most people, that tank must be kept hot at a price too. IIRC the publicity was that you could get hot water "faster" which is a question of a very little difference if any IMO.

    A tankless electric, interesting, why not, we have 220V/32A lines in the kitchen, I wonder how well that would work out.

  • source
  • parent
  • context
  • [–] 30 points 1 year ago (8 children)

    That's only true in America, where your Health and Safety Standards are shit.

    Might be true in parts of Africa and China too, along with other places with a bad standard of human rights.

  • source
  • [–] 15 points 1 year ago (4 children)

    Chemical engineer here. The difference in temperature between your cold and hot water supplies is what the problem is, and I would imagine this is not a problem at all in modern plumbing systems. Your cold water supply is usually about 50-60 deg F (10-15 C) while your hot water supply us usually set to 140 F (60 C). Solubility of some lead salts in water are given in this table with lead chloride being about 0.8 g/100mL at 10 C and 1.98 g/100mL at 60 C, so about 2.5x more soluble. The rate itself is a more complicated relationship, but it increases rapidly as well. Temperature has a big effect on these things.

  • source
  • parent
  • context
  • [–] 15 points 1 year ago (1 child)

    When I moved into my house, I ran tests on my tap water, and found that my hot water had higher levels of iron and other metals dissolved in it. This is likely corrosion from the water heater tank. After I replaced the anode rod, the tests came out nearly identical.

    All of the levels I found were within the legal limits for human consumption, so it would've been fine... But maybe there are cases where that isn't true. The tests were very cheap, and Home Depot near me offers a 3 test kit (including lead) for free, near the water filter section. It's worth testing to be certain.

  • source
  • parent
  • context
  • [–] 20 points 1 year ago (8 children)

    This seems....questionable. The entire information given is two sentences. This seems like something an eighth grader wrote for a school project.

    'Hot water dissolves lead faster'. Ok, how much faster? I feel like the trip from the water heater to my sink is negligible even if I had lead pipes, which I don't.

    If anyone has anything more substantial, please post it.

  • source
  • [–] 2 points 1 year ago

    Yeah the real reason is that the inside of a hot water storage tank is nasty. Because of the way heat flows up, the hot water fills from the bottom and drains from the top. All the sediment and dirt and minerals collect at the bottom.