For those of you without an electrical background, the diagram shows the protective earth connected directly to phase, with phase and neutral also joined.

Correctly wired, this would be a three pin plug, with the earth wire connected to the earth pin in the plug, with the other end connected to the metal casing of the appliance. This is a critical safety feature, which will cause the circuit protection to trip in the event a phase wire contacts the metal of whatever this is connected to.

If this was actually done, the most likely outcome is it would trip a circuit breaker, but if the neutral was broken, it would connect phase directly to the casing, and likely electrocute someone.